Fracture resistance and failure modes of CEREC endo-crowns and conventional post and core-supported CEREC crowns
Article Outline
Background/Purpose
The purpose of this in vitro study was to compare the fracture resistance and failure modes of CEREC endo-crowns with the CEREC classic designed crown supported with glass fiber-reinforced composite posts and composite cores. The influences of thermal cycling and fatigue loading on both types of restorations were also investigated.
Materials and methods
Twenty extracted intact maxillary premolars were randomly divided into two groups (C and E). The crown portion of the specimens was removed to 1.5 mm above the cementoenamel junction (CEJ). All specimens were endodontically treated with a nickel-titanium rotary system and obturated with gutta-percha by a vertical compaction technique. In group C (n = 10), teeth were restored with glass fiber-reinforced composite posts and composite cores with a 1.0-mm wide circumferential shoulder margin at the CEJ and a 1.5-mm ferrule. In group E (n = 10), teeth were prepared for fabrication of CEREC endo-crowns. Both types of ceramic crowns were produced from ProCAD ceramic blocks utilizing a CEREC 3D CAD-CAM unit, and these were bonded to the preparations with an adhesive system and composite resin cement. Teeth were thermally cycled (2000 cycles of 5°C/55°C with a dwell time of 30 seconds,) and fatigue loaded (20,000 cycles at 5 kg and 3 Hz) in a custom-made fatigue simulator. All specimens were loaded in a universal testing machine with a cross-head speed of 0.5 mm/s until fracture occurred. Fracture resistance and failure modes were statistically evaluated with a t test and χ2 test.
Results
The mean fracture resistance ± standard deviation was recorded as follows: 1163.30±163.15 N for group C and 1446.68±200.34 N for group E. A significant difference was found between groups with respect to fracture resistance (P < 0.05). Regarding failure modes, most specimens of both groups exhibited unfavorable fractures, and no significant difference was found between the two groups.
Conclusion
The bonded ceramic endo-crowns showed a significantly higher fracture resistance than the classic reinforced and designed group and, therefore, offer a feasible alternative for severely damaged teeth.
Key Words: CAD-CAM , CEREC , endo-crown , failure modes , fracture resistance
No full text is available. To read the body of this article, please view the PDF online.
References
- . Post placement and restoration of endodontically treated teeth: a literature review . J Endod . 2004;30:289–301
- . Moisture content of vital vs endodontically treated teeth . Endod Dent Traumatol . 1994;10:91–93
- . Effects of moisture content and endodontic treatment on some mechanical properties of human dentin . J Endod . 1992;18:209–215
- . Reduction in tooth stiffness as a result of endodontic restorative procedures . J Endod . 1989;15:512–516
- . Cuspal deflection in molars in relation to endodontic and restorative procedures . J Endod . 1995;21:57–61
- . An investigation of cuspal deformation and delayed recovery after occlusal loading . J Dent . 2001;29:363–370
- . The dentin-root complex: anatomic and biologic considerations in restoring endodontically treated teeth . J Prosthet Dent . 1992;67:458–467
- . Influence of restorative technique on the biomechanical behavior of endodontically treated maxillary premolars, part I: fracture resistance and fracture mode . J Prosthet Dent . 2008;99:30–37
- . Post-endodontic restorations with adhesively luted fiber-reinforced composite post systems: a review . Am J Dent . 2007;20:353–360
- . Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature, part I: composition and micro-and macrostructure alterations . Quintessence Int . 2007;38:733–743
- . Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature, part II: evaluation of fatigue behavior, interfaces, and in vivo studies . Quintessence Int . 2008;39:117–129
- . Ferrule design and fracture resistance of endodontically treated teeth . J Prosthet Dent . 1990;63:529–536
- . Effects of post-core design and ferrule on fracture resistance of endodontically treated maxillary central incisors . J Prosthet Dent . 2003;89:368–373
- . Restoration of endodontically treated teeth . Dent Clin North Am . 1992;36:631–650
- . Effect of crown lengthening and ferrule placement on static load failure of cemented cast post-cores and crowns . J Prosthet Dent . 2000;84:169–179
- . Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years—preliminary results . J Adhes Dent . 1999;1:255–265
- . Fabrication of a metal-free ceramic restoration utilizing the monobloc technique . Pract Periodontics Aesthet Dent . 1995;7:83–94
- . Effect of preparation and luting system on all-ceramic computer-generated crowns . Int J Prosthodont . 1998;11:333–339
- Deesri W, Kunzelmann KH, Ilie N, Hickel R. Fracture strength and Weibull evaluation of the Cerec endocrowns and post-and-core-supported conventional Cerec crowns (abstract 0872). Proceedings of the 81st General Session of the International Association for Dental Research, June 25–28, 2003, Goteborg, Sweden.
- . Endocrowns: a clinical report . Quintessence Int . 2008;39:99–106
- . Restoring endodontically treated teeth with all-ceramic endo-crowns—case report . Stom Glas S . 2008;55:54–64
- . Computer-aided direct all-ceramic crowns: preliminary 1-year results of a prospective clinical study . Int J Periodontics Restorative Dent . 2004;24:446–455
- . Restoration endodontically treated teeth without posts . Am J Dent . 2003;16:313–318
- . Restoration of an endodontically treated tooth utilizing a single-unit crown and core system . Pract Periodontics Aesthet Dent . 2000;12:105–108
- . Pattern of indirect fracture in intact and restored human premolar teeth . Endod Dent Traumatol . 1987;3:10–14
- . Moisture assisted crack growth in ceramics . Int J Fract Mech . 1968;4:171–177
- . Effects of surface finish and fatigue testing on the fracture strength of CAD-CAM and pressed-ceramic crowns . J Prosthet Dent . 1999;82:468–475
- . Ex vivo fracture resistance of direct resin composite complete crowns with and without posts on maxillary premolars . Int Endod J . 2005;38:230–237
- Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges . Oper Dent . 2003;28:215–235
- . Strength of adhesive-bonded fiber-reinforced composites to enamel and dentin substrates . J Adhes Dent . 2003;5:301–311
- . Influence of glass-ceramic thickness on Hertzian and bulk fracture mechanisms . Int J Prosthodont . 1998;11:27–32
- . Maximal bite force with centric and eccentric load . J Oral Rehabil . 1982;9:445–450
- . Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure . J Dent Res . 1999;78:1336–1344
- . Fracture resistance of endodontically treated maxillary premolars restored with CAD/CAM ceramic inlays . J Prosthet Dent . 2005;94:342–349
- . Survival of ceramic computer-aided design/manufacturing crowns bonded to preparations with reduced macroretention geometry . Int J Prosthodont . 2005;18:219–224
- Evaluation of the biomechanical behavior of maxillary central incisors restored by means of endocrowns compared to a natural tooth: a 3D static linear finite elements analysis . Dent Mater . 2006;22:1035–1044
- . The wear of dental amalgam in an artificial mouth: a clinical correlation . Dent Mater . 1985;1:238–242
- . The wear of a posterior dental composite in an artificial mouth: a clinical correlation . Dent Mater . 1986;2:235–240
- . All-ceramic, chair-side computeraided design/computer-aided machining restorations . Dent Clin North Am . 2002;46:405–426
PII: S1991-7902(09)60016-7
doi:10.1016/S1991-7902(09)60016-7
© 2009 Association for Dental Sciences of The Republic of China. Published by Elsevier Inc. All rights reserved.