Journal of Dental Sciences
Volume 4, Issue 3 , Pages 110-117, September 2009

Fracture resistance and failure modes of CEREC endo-crowns and conventional post and core-supported CEREC crowns

  • Chia-Yu Chang

      Affiliations

    • Department of Operative Dentistry, Chang Gung Memorial Hospital, Tao-Yuan, Taiwan
  • ,
  • Jau-Shing Kuo

      Affiliations

    • Department of Operative Dentistry, Chang Gung Memorial Hospital, Tao-Yuan, Taiwan
  • ,
  • Yang-Sung Lin

      Affiliations

    • Department of Mechanical Engineering, Chang Gung University, Kweishan, Taoyuan, Taiwan
  • ,
  • Yen-Hsiang Chang

      Affiliations

    • Department of Operative Dentistry, Chang Gung Memorial Hospital, Tao-Yuan, Taiwan
    • Corresponding Author InformationCorresponding author. Department of Operative Dentistry, Chang Gung Memorial Hospital, 123, Ding-Hu Road, Kueishan, Taoyuan 33345, Taiwan

Received 14 May 2009; accepted 15 August 2009.

Article Outline

Background/Purpose

The purpose of this in vitro study was to compare the fracture resistance and failure modes of CEREC endo-crowns with the CEREC classic designed crown supported with glass fiber-reinforced composite posts and composite cores. The influences of thermal cycling and fatigue loading on both types of restorations were also investigated.

Materials and methods

Twenty extracted intact maxillary premolars were randomly divided into two groups (C and E). The crown portion of the specimens was removed to 1.5 mm above the cementoenamel junction (CEJ). All specimens were endodontically treated with a nickel-titanium rotary system and obturated with gutta-percha by a vertical compaction technique. In group C (n = 10), teeth were restored with glass fiber-reinforced composite posts and composite cores with a 1.0-mm wide circumferential shoulder margin at the CEJ and a 1.5-mm ferrule. In group E (n = 10), teeth were prepared for fabrication of CEREC endo-crowns. Both types of ceramic crowns were produced from ProCAD ceramic blocks utilizing a CEREC 3D CAD-CAM unit, and these were bonded to the preparations with an adhesive system and composite resin cement. Teeth were thermally cycled (2000 cycles of 5°C/55°C with a dwell time of 30 seconds,) and fatigue loaded (20,000 cycles at 5 kg and 3 Hz) in a custom-made fatigue simulator. All specimens were loaded in a universal testing machine with a cross-head speed of 0.5 mm/s until fracture occurred. Fracture resistance and failure modes were statistically evaluated with a t test and χ2 test.

Results

The mean fracture resistance ± standard deviation was recorded as follows: 1163.30±163.15 N for group C and 1446.68±200.34 N for group E. A significant difference was found between groups with respect to fracture resistance (P < 0.05). Regarding failure modes, most specimens of both groups exhibited unfavorable fractures, and no significant difference was found between the two groups.

Conclusion

The bonded ceramic endo-crowns showed a significantly higher fracture resistance than the classic reinforced and designed group and, therefore, offer a feasible alternative for severely damaged teeth.

Key Words:  CAD-CAM , CEREC , endo-crown , failure modes , fracture resistance

No full text is available. To read the body of this article, please view the PDF online.

 

Back to Article Outline

References 

  1. Schwartz RS , Robbins JW . Post placement and restoration of endodontically treated teeth: a literature review . J Endod . 2004;30:289–301
  2. Papa J , Cain C , Messer HH . Moisture content of vital vs endodontically treated teeth . Endod Dent Traumatol . 1994;10:91–93
  3. Huang TJ , Schilder H , Nathanson D . Effects of moisture content and endodontic treatment on some mechanical properties of human dentin . J Endod . 1992;18:209–215
  4. Reeh ES , Messer HH , Douglas WH . Reduction in tooth stiffness as a result of endodontic restorative procedures . J Endod . 1989;15:512–516
  5. Panitvisai P , Messer HH . Cuspal deflection in molars in relation to endodontic and restorative procedures . J Endod . 1995;21:57–61
  6. Jantarat J , Palamara JE , Messer HH . An investigation of cuspal deformation and delayed recovery after occlusal loading . J Dent . 2001;29:363–370
  7. Gutmann JL . The dentin-root complex: anatomic and biologic considerations in restoring endodontically treated teeth . J Prosthet Dent . 1992;67:458–467
  8. Soares PV , Santos-Filho PC , Martins LR , Soares CJ . Influence of restorative technique on the biomechanical behavior of endodontically treated maxillary premolars, part I: fracture resistance and fracture mode . J Prosthet Dent . 2008;99:30–37
  9. Bitter K , Kielbassa AM . Post-endodontic restorations with adhesively luted fiber-reinforced composite post systems: a review . Am J Dent . 2007;20:353–360
  10. Dietschi D , Duc O , Krejci I , Sadan A . Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature, part I: composition and micro-and macrostructure alterations . Quintessence Int . 2007;38:733–743
  11. Dietschi D , Duc O , Krejci I , Sadan A . Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature, part II: evaluation of fatigue behavior, interfaces, and in vivo studies . Quintessence Int . 2008;39:117–129
  12. Sorensen JA , Engelman MJ . Ferrule design and fracture resistance of endodontically treated teeth . J Prosthet Dent . 1990;63:529–536
  13. Zhi-Yue L , Yu-Xing Z . Effects of post-core design and ferrule on fracture resistance of endodontically treated maxillary central incisors . J Prosthet Dent . 2003;89:368–373
  14. Sivers JE , Johnson WT . Restoration of endodontically treated teeth . Dent Clin North Am . 1992;36:631–650
  15. Gegauff AG . Effect of crown lengthening and ferrule placement on static load failure of cemented cast post-cores and crowns . J Prosthet Dent . 2000;84:169–179
  16. Bindl A , Mörmann WH . Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years—preliminary results . J Adhes Dent . 1999;1:255–265
  17. Pissis P . Fabrication of a metal-free ceramic restoration utilizing the monobloc technique . Pract Periodontics Aesthet Dent . 1995;7:83–94
  18. Mörmann WH , Bindl A , Lüthy H , Rathke A . Effect of preparation and luting system on all-ceramic computer-generated crowns . Int J Prosthodont . 1998;11:333–339
  19. Deesri W, Kunzelmann KH, Ilie N, Hickel R. Fracture strength and Weibull evaluation of the Cerec endocrowns and post-and-core-supported conventional Cerec crowns (abstract 0872). Proceedings of the 81st General Session of the International Association for Dental Research, June 25–28, 2003, Goteborg, Sweden.
  20. Lander E , Dietschi D . Endocrowns: a clinical report . Quintessence Int . 2008;39:99–106
  21. Valentina V , Aleksandar T , Dejan L , Vojkan L . Restoring endodontically treated teeth with all-ceramic endo-crowns—case report . Stom Glas S . 2008;55:54–64
  22. Otto T . Computer-aided direct all-ceramic crowns: preliminary 1-year results of a prospective clinical study . Int J Periodontics Restorative Dent . 2004;24:446–455
  23. Göhring TN , Peters OA . Restoration endodontically treated teeth without posts . Am J Dent . 2003;16:313–318
  24. Adams T . Restoration of an endodontically treated tooth utilizing a single-unit crown and core system . Pract Periodontics Aesthet Dent . 2000;12:105–108
  25. Salis SG , Hodd JA , Stokes AN , Kirk EE . Pattern of indirect fracture in intact and restored human premolar teeth . Endod Dent Traumatol . 1987;3:10–14
  26. Wiederhorn SM . Moisture assisted crack growth in ceramics . Int J Fract Mech . 1968;4:171–177
  27. Chen HY , Hickel R , Setcos JC , Kunzelmann KH . Effects of surface finish and fatigue testing on the fracture strength of CAD-CAM and pressed-ceramic crowns . J Prosthet Dent . 1999;82:468–475
  28. Fokkinga WA , Le Bell AM , Kreulen CM , Lassila LV , Vallittu PK , Creugers NH . Ex vivo fracture resistance of direct resin composite complete crowns with and without posts on maxillary premolars . Int Endod J . 2005;38:230–237
  29. Van Meerbeek B , De Munck J , Yoshida Y , et al.   Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges . Oper Dent . 2003;28:215–235
  30. Tezvergil A , Lassila LV , Vallittu PK . Strength of adhesive-bonded fiber-reinforced composites to enamel and dentin substrates . J Adhes Dent . 2003;5:301–311
  31. Tsai YL , Petsche PE , Anusavice KJ , Yang MC . Influence of glass-ceramic thickness on Hertzian and bulk fracture mechanisms . Int J Prosthodont . 1998;11:27–32
  32. Widmalm SE , Ericsson SG . Maximal bite force with centric and eccentric load . J Oral Rehabil . 1982;9:445–450
  33. Hidaka O , Iwasaki M , Saito M , Morimoto T . Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure . J Dent Res . 1999;78:1336–1344
  34. Hannig C , Westphal C , Becker K , Attin T . Fracture resistance of endodontically treated maxillary premolars restored with CAD/CAM ceramic inlays . J Prosthet Dent . 2005;94:342–349
  35. Bindl A , Richter B , Mörmann WH . Survival of ceramic computer-aided design/manufacturing crowns bonded to preparations with reduced macroretention geometry . Int J Prosthodont . 2005;18:219–224
  36. Zarone F , Sorrentino R , Apicella D , et al.   Evaluation of the biomechanical behavior of maxillary central incisors restored by means of endocrowns compared to a natural tooth: a 3D static linear finite elements analysis . Dent Mater . 2006;22:1035–1044
  37. DeLong R , Sakaguchi RL , Douglas WH , Pintado MR . The wear of dental amalgam in an artificial mouth: a clinical correlation . Dent Mater . 1985;1:238–242
  38. Sakaguchi RL , Douglas WH , DeLong R , Pintado MR . The wear of a posterior dental composite in an artificial mouth: a clinical correlation . Dent Mater . 1986;2:235–240
  39. Mörmann WH , Bindl A . All-ceramic, chair-side computeraided design/computer-aided machining restorations . Dent Clin North Am . 2002;46:405–426

PII: S1991-7902(09)60016-7

doi:10.1016/S1991-7902(09)60016-7

Journal of Dental Sciences
Volume 4, Issue 3 , Pages 110-117, September 2009